USAfixTM - Repair Guide (RG) - Master Email RG
- Test the Stepboard Switch
 Level of Difficulty - HIGH  Estimated Completion Time - 5 minutes
TASKI - SWINGO XP

Tools Required
Tool 
Volt meter (True RMS capable)
Wrench-Allen metric 5.0mm

Parts Required


Step Procedure & Parts & Tools
1 Turn the machine off.

2 Using a 5mm Allen wrench, remove the 3 screws from the power electronics.
Wrench-Allen metric 5.0mm

3 Pull to remove the power electronics.

4 Pull to unplug the plug labeled stepboard.

5 Turn the machine on.

6 Using the volt meter, plug the contactors into the stepboard plug. If the volt meter beeps, the limit switch is good. If it doesn’t beep, replace the limit switch.
Volt meter (True RMS capable)